Gen4 Emergency LED T8 Tube

(For On/Off Applications)

Aleddra’s Gen4 Emergency LED T8 tube sets another industry standard as the first fully automatic self-testing/self-diagnosis T8. The lamp operates as an energy-efficient T8 during normal operation and can be turned on/off via a wall switch. During power outage, it will last over 90 minutes on battery. More importantly, the lamp will automatically self-test for 30 seconds monthly and for 90 minutes annually, thus meeting the emergency lighting audit requirements with no labor cost. This saves a facility management team a tremendous amount of labor from manually testing every single lamp of this kind in its facilities. Should any malfunction be detected during self-testing, such as insufficient battery capacity, the warning indicator on the lamp will flash and alert the team. With its labor saving, the lamp gives the end user the best return on investment and the best emergency lighting option. Please follow the installation instruction to wire the lamp.

LISTINGS AND CERTIFICATIONS

        

  • ETL certified for Type B (ballast bypass)
  • DLC 5.1 Listed
  • IES Progress Report 2020 Selection
  • 90 minutes battery time per industry standard
FEATURES
  • 2-in-1 tube: regular T8 lighting and emergency lighting
  • Fully automatic self-testing: 30-second test monthly and 90-minute test annually
  • Fully automatic self-diagnosis with flashing indicator if the battery time drops below 90 minutes
  • Manual testing button
  • Built-in lithium batteries
  • Controllable by wall switch
  • Easy battery shutoff switch for a long stocking time
  • Patented (for details, please see here.)
Z

SPECIFICATIONS

Length2ft / 4ftColor3000K-6000KLED TypeSMD2835
CRI>80Input VoltageAC100-277VBattery Operating Temperature68ºF to 104ºF
Battery Backup Time90 minutesWattage15WLight Output1800lm
Power Factor>0.92Luminous Efficiency>120lm/WLight Output When on Battery420lm at 3.5W
Warranty5-year *Rated Hours50,000 hours

 

* The 5-year warranty is provided under the assumption of performing no more than two 90-min battery discharge tests annually over five years. The warranty is void if performing more than ten 90-min battery discharge tests in five years.

** The Emergency Tube meets the performance requirements of UL924 but not UL924 certified because it is an attachable emergency lighting equipment.

Z

ORDER INFORMATION

Product NumberWattageColor TemperatureLength
LLT-2-EM-T8-G4-8W-40K8W4000K2ft
LLT-2-EM-T8-G4-8W-50K8W5000K2ft
LLT-4-EM-T8-G4-15W-30K15W3000K4ft
LLT-4-EM-T8-G4-15W-35K15W3500K4ft
LLT-4-EM-T8-G4-15W-40K15W4000K4ft
LLT-4-EM-T8-G4-15W-50K15W5000K4ft
LLT-4-EM-T8-G4-15W-60K15W6000K4ft